Power System Analysis and Design (MindTap Course List)
Power System Analysis and Design (MindTap Course List)
6th Edition
ISBN: 9781305632134
Author: J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher: Cengage Learning
Question
Book Icon
Chapter 4, Problem 4.11P
To determine

(a)

The value of positive sequence inductance and the positive sequence inductive reactance.

Compare the results with the case when phase spacing is 4ft.

To determine

(b)

The value of positive sequence inductance and the positive sequence inductive reactance.

Compare the results with the case when phase spacing is 4ft.

Blurred answer
Students have asked these similar questions
please solve for nodal stress method. (if it is possible to apply supernodes)
Q4 (a) (b) A 4-bus power system, as shown in Figure Q4a, of which the parameters are given in Table Q4a; the p.u. value of every component is given based on its own base values (rating). i) Draw an impedance diagram of the network, showing all impedances in p.u., on 1000 MVA and 20 kV base values in the Generator G3 zone. A three-phase short circuit occurs at busbar 3 through a rearance of j0.12 p.u., where the pre-fault voltage is 525 kV and the pre-fault current is neglected. Calculate the short circuit current in p.u. using Thevenin's Theorem. Describe the data required for each component of a typical power network when analysing faults, and the reasons for needing each item of data. T, bus 1 ∞to ΔΥ G₁ G₂ G3 T₁ T₂ Тз Transmission line: 150 Ω bus 4 T₂ bus 2 150 Ω 150 Ω G₂ YE bus 3 T₂ 머( YEA Figure 04a 500 MVA, 13.8 kV, XG1= 0.20 p.u. 750 MVA, 18 kV, XG2 = 0.18 p.u. 1000 MVA, 20 kV, XG3 = 0.17 p.u. 500MVA, 13.8 (A) /500 kV, XT1 = 0.12 p.u. 750 MVA, 18 (A) /500 kV, XT2 = 0.10 p.u. 1000…
A network consisting of a set of generator and load buses is to be modeled with a DC power flow, for the sake of conducting a contingency analysis. The initial flows calculated with the DC power flow give the following information: f°2-4 = - 65.3 MW and fº4-5 = 13.6 MW. The following values of LODF and PTDF factors are given: PTDF54,2-4 = -0.2609, LODF2-4,4-5 = -0.6087. Calculate the contingency flow on line 2-4 due to outage of line 4-5. Select one: O a. -75.5MW O b. None of these O c. -68.85MW O d. -73.58MW O e. 75.5MW O f. -61.75MW

Chapter 4 Solutions

Power System Analysis and Design (MindTap Course List)

Ch. 4 - Prob. 4.11MCQCh. 4 - Prob. 4.12MCQCh. 4 - For a single-phase, two-wire line consisting of...Ch. 4 - For a three-phase three-wire line consisting of...Ch. 4 - For a balanced three-phase positive-sequence...Ch. 4 - A stranded conductor is an example of a composite...Ch. 4 - lnAk=lnAk True FalseCh. 4 - Prob. 4.18MCQCh. 4 - Expand 6k=13m=12Dkm.Ch. 4 - Prob. 4.20MCQCh. 4 - For a single-phase two-conductor line with...Ch. 4 - In a three-phase line, in order to avoid unequal...Ch. 4 - For a completely transposed three-phase line...Ch. 4 - Prob. 4.24MCQCh. 4 - Does bundling reduce the series reactance of the...Ch. 4 - Does r=e14r=0.788r, which comes in calculation of...Ch. 4 - In terms of line-to-line capacitance, the...Ch. 4 - For either single-phase two-wire line or balanced...Ch. 4 - Prob. 4.29MCQCh. 4 - Prob. 4.30MCQCh. 4 - Prob. 4.31MCQCh. 4 - Prob. 4.32MCQCh. 4 - Prob. 4.33MCQCh. 4 - Prob. 4.34MCQCh. 4 - The affect of the earth plane is to slightly...Ch. 4 - When the electric field strength at a conductor...Ch. 4 - Prob. 4.37MCQCh. 4 - Prob. 4.38MCQCh. 4 - Considering two parallel three-phase circuits that...Ch. 4 - The Aluminum Electrical Conductor Handbook lists a...Ch. 4 - The temperature dependence of resistance is also...Ch. 4 - A transmission-line cable with a length of 2 km...Ch. 4 - One thousand circular mils or 1 kcmil is sometimes...Ch. 4 - A 60-Hz, 765-kV, three-phase overhead transmission...Ch. 4 - A three-phase overhead transmission line is...Ch. 4 - If the per-phase line loss in a 70-km-long...Ch. 4 - A 60-Hz, single-phase two-wire overhead line has...Ch. 4 - Prob. 4.9PCh. 4 - A 60-Hz, three-phase three-wire overhead line has...Ch. 4 - Prob. 4.11PCh. 4 - Find the inductive reactance per mile of a...Ch. 4 - A single-phase overhead transmission line consists...Ch. 4 - Prob. 4.14PCh. 4 - Find the GMR of a stranded conductor consisting of...Ch. 4 - Prob. 4.16PCh. 4 - Determine the GMR of each of the unconventional...Ch. 4 - A 230-kV, 60-Hz, three-phase completely transposed...Ch. 4 - Prob. 4.19PCh. 4 - Calculate the inductive reactance in /km of a...Ch. 4 - Rework Problem 4.20 if the bundled line has (a)...Ch. 4 - Prob. 4.22PCh. 4 - Prob. 4.23PCh. 4 - Prob. 4.24PCh. 4 - For the overhead line of configuration shown in...Ch. 4 - Prob. 4.26PCh. 4 - Figure 4.34 shows double-circuit conductors'...Ch. 4 - For the case of double-circuit, bundle-conductor...Ch. 4 - Prob. 4.29PCh. 4 - Figure 4.37 shows the conductor configuration of a...Ch. 4 - Prob. 4.32PCh. 4 - Prob. 4.33PCh. 4 - Prob. 4.34PCh. 4 - Prob. 4.35PCh. 4 - Prob. 4.36PCh. 4 - Prob. 4.38PCh. 4 - Calculate the capacitance-to-neutral in F/m and...Ch. 4 - Prob. 4.40PCh. 4 - Prob. 4.41PCh. 4 - Prob. 4.42PCh. 4 - Three ACSR Drake conductors are used for a...Ch. 4 - Consider the line of Problem 4.25. Calculate the...Ch. 4 - Prob. 4.45PCh. 4 - Prob. 4.46PCh. 4 - Prob. 4.47PCh. 4 - The capacitance of a single-circuit, three-phase...Ch. 4 - Prob. 4.49PCh. 4 - Prob. 4.50PCh. 4 - Prob. 4.51PCh. 4 - Approximately how many physical transmission...Ch. 4 - Prob. BCSQCh. 4 - Prob. CCSQCh. 4 - Prob. DCSQ
Knowledge Booster
Background pattern image
Similar questions
SEE MORE QUESTIONS
Recommended textbooks for you
Text book image
Power System Analysis and Design (MindTap Course ...
Electrical Engineering
ISBN:9781305632134
Author:J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:Cengage Learning