Required information NOTE: This is a multi-part question. Once an answer is submitted, you will be unable to return to this part. A 0.051-m³ rigid tank initially contains refrigerant-134a at 0.8 MPa and 100 percent quality. The tank is connected by a valve to a supply line that carries refrigerant-134a at 1.2 MPa and 40°C. Now the valve is opened, and the refrigerant is allowed to enter the tank. The valve is closed when it is observed that the tank contains saturated liquid at 1.2 MPa. The properties of refrigerant are ₁ = 0.02565 m³/kg, u₁ = 246.82 kJ/kg, 2 = 0.0008935 m³/kg, u2 = 116.72 kJ/kg, and h;= 108.28 kJ/kg. Determine the mass of the refrigerant that has entered the tank. (You must provide an answer before moving on to the next part.) The mass of the refrigerant is kg.

College Physics
1st Edition
ISBN:9781938168000
Author:Paul Peter Urone, Roger Hinrichs
Publisher:Paul Peter Urone, Roger Hinrichs
Chapter15: Thermodynamics
Section: Chapter Questions
Problem 63PE: (a) Construct a table showing the macro states and all of the individual microstates for tossing 13...
icon
Related questions
Question
Required information
NOTE: This is a multi-part question. Once an answer is submitted, you will be unable to return to this part.
A 0.051-m³ rigid tank initially contains refrigerant-134a at 0.8 MPa and 100 percent quality. The tank is connected by a
valve to a supply line that carries refrigerant-134a at 1.2 MPa and 40°C. Now the valve is opened, and the refrigerant is
allowed to enter the tank. The valve is closed when it is observed that the tank contains saturated liquid at 1.2 MPa. The
properties of refrigerant are ₁ = 0.02565 m³/kg, u₁ = 246.82 kJ/kg, 2 = 0.0008935 m³/kg, u2 = 116.72 kJ/kg, and h;=
108.28 kJ/kg.
Determine the mass of the refrigerant that has entered the tank. (You must provide an answer before moving on to the next part.)
The mass of the refrigerant is
kg.
Transcribed Image Text:Required information NOTE: This is a multi-part question. Once an answer is submitted, you will be unable to return to this part. A 0.051-m³ rigid tank initially contains refrigerant-134a at 0.8 MPa and 100 percent quality. The tank is connected by a valve to a supply line that carries refrigerant-134a at 1.2 MPa and 40°C. Now the valve is opened, and the refrigerant is allowed to enter the tank. The valve is closed when it is observed that the tank contains saturated liquid at 1.2 MPa. The properties of refrigerant are ₁ = 0.02565 m³/kg, u₁ = 246.82 kJ/kg, 2 = 0.0008935 m³/kg, u2 = 116.72 kJ/kg, and h;= 108.28 kJ/kg. Determine the mass of the refrigerant that has entered the tank. (You must provide an answer before moving on to the next part.) The mass of the refrigerant is kg.
Expert Solution
trending now

Trending now

This is a popular solution!

steps

Step by step

Solved in 2 steps with 1 images

Blurred answer
Similar questions
  • SEE MORE QUESTIONS
Recommended textbooks for you
College Physics
College Physics
Physics
ISBN:
9781938168000
Author:
Paul Peter Urone, Roger Hinrichs
Publisher:
OpenStax College
University Physics Volume 2
University Physics Volume 2
Physics
ISBN:
9781938168161
Author:
OpenStax
Publisher:
OpenStax
Physics for Scientists and Engineers: Foundations…
Physics for Scientists and Engineers: Foundations…
Physics
ISBN:
9781133939146
Author:
Katz, Debora M.
Publisher:
Cengage Learning