Identify the mistakes in the pictures. Explain.

Power System Analysis and Design (MindTap Course List)
6th Edition
ISBN:9781305632134
Author:J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Chapter3: Power Transformers
Section: Chapter Questions
Problem 3.33MCQ: The direct electrical connection of the windings allows transient over voltages to pass through the...
icon
Related questions
Question

Identify the mistakes in the pictures. Explain.

1. THE ELECTRICAL INSTALLATION SHOWN ON THE PLANS SHALL CONFORM
WITH THE LATEST EDITION OF THE PHILIPPINE ELECTRICAL CODE, RULES
AND REGULATIONS OF THE LOCAL ELECTRIC COMPANY AND THE LOCAL
GOVERNMENT WHERE THE PROJECT WILL BE CONSTRUCTED.
2. ALL ELECTRICAL MATERIALS AND EQUIPMENT TO BE USED IN THIS
PROJECT SHALL BE BRAND-NEW AND OF APPROVED QUALITY AND BRAND.
3. THE ELECTRIC WIRINGS INSIDE THE BUILDING SHALL BE THROUGH PVC
CONDUIT PIPES NOT SMALLER THAN 20mm DIAMETER, SCHEDULE 40.
4. THERE SHALL BE ONLY ONE SERVICE DROP FROM THE NEAREST
ELECTRIC COMPANY POLE TO THE PROPOSED BUILDING.
5. WIRES TO BE USED INSIDE THE BUILDING SHALL NOT BE SMALLER THAN
3.5sq.mm. WITH 600V INSULATION.
6. THE TYPE OF POWER SERVICE TO BE SUPPLIED SHALL BE SINGLE PHASE,
220V, A.C.
7. MOUNTING HEIGHT OF ELECTRICAL DEVICES SHALL BE AS FOLLOWS:
a. WALL SWITCHES ----
b. CONVENIENCE OUTLETS-----.30 METER ABOVE FLOOR LINE
--1.37 METERS ABOVE FLOOR LINE
c. AIRCONDITIONING OUTLET--2.00 METERS ABOVE FLOOR LINE
d. PANEL BOARD---
e. KILOWATT-HOUR METER---1.85 METERS FROM GROUND TO CENTER
--1.37 METERS ABOVE FLOOR LINE
OF METER
f. WASHING MACHINE OUTLET- 1.5 METERS FROM FLOOR LINE
E GENERAL NOTES/ SPECIFICATION
2
Transcribed Image Text:1. THE ELECTRICAL INSTALLATION SHOWN ON THE PLANS SHALL CONFORM WITH THE LATEST EDITION OF THE PHILIPPINE ELECTRICAL CODE, RULES AND REGULATIONS OF THE LOCAL ELECTRIC COMPANY AND THE LOCAL GOVERNMENT WHERE THE PROJECT WILL BE CONSTRUCTED. 2. ALL ELECTRICAL MATERIALS AND EQUIPMENT TO BE USED IN THIS PROJECT SHALL BE BRAND-NEW AND OF APPROVED QUALITY AND BRAND. 3. THE ELECTRIC WIRINGS INSIDE THE BUILDING SHALL BE THROUGH PVC CONDUIT PIPES NOT SMALLER THAN 20mm DIAMETER, SCHEDULE 40. 4. THERE SHALL BE ONLY ONE SERVICE DROP FROM THE NEAREST ELECTRIC COMPANY POLE TO THE PROPOSED BUILDING. 5. WIRES TO BE USED INSIDE THE BUILDING SHALL NOT BE SMALLER THAN 3.5sq.mm. WITH 600V INSULATION. 6. THE TYPE OF POWER SERVICE TO BE SUPPLIED SHALL BE SINGLE PHASE, 220V, A.C. 7. MOUNTING HEIGHT OF ELECTRICAL DEVICES SHALL BE AS FOLLOWS: a. WALL SWITCHES ---- b. CONVENIENCE OUTLETS-----.30 METER ABOVE FLOOR LINE --1.37 METERS ABOVE FLOOR LINE c. AIRCONDITIONING OUTLET--2.00 METERS ABOVE FLOOR LINE d. PANEL BOARD--- e. KILOWATT-HOUR METER---1.85 METERS FROM GROUND TO CENTER --1.37 METERS ABOVE FLOOR LINE OF METER f. WASHING MACHINE OUTLET- 1.5 METERS FROM FLOOR LINE E GENERAL NOTES/ SPECIFICATION 2
TUBULAR OR COMPACT FLOURESSCENT LIGHT
PINLIGHT WITH COMPACT FLOURESCENT BULB
DUPLEX CONVENIENCE OUTLET
WP O WEATHER PROOF DUPLEX CcONVENIENCE OUTLET
REFO REFRIGERATOR OUTLET
Re THREE-PRONGS COOKING RANGE OUTLET
ACUO AIRCONDITIONING OUTLET
CIRCUIT HOMERUN FOR LIGHTING
(NUMBERS INSIDE CIRCLES IDENTIFY THE CIRCUITS)
CIRCUIT HOMERUN FOR APPLIANCE OUTLETS
S3w THREE-WAY SWITCH
WHO WATER HEATER OUTLET
WMO WASHING MACHINE WITH DRYER OUTLET
LPP I LIGHTING AND POWER PANELBOARD
Q TV ANTENNA OUTLET
MATVE MASTER ANTENNA TV OUTLET/ CABINET
TTC E TELEPHONE TERMINAL CABINET
TELEPHONE OUTLET
V TELEPHONE EXTENSION/ INTERCOMMUNICATION
E LEGEND/ ELECTRICAL SYMBOLS
1
Transcribed Image Text:TUBULAR OR COMPACT FLOURESSCENT LIGHT PINLIGHT WITH COMPACT FLOURESCENT BULB DUPLEX CONVENIENCE OUTLET WP O WEATHER PROOF DUPLEX CcONVENIENCE OUTLET REFO REFRIGERATOR OUTLET Re THREE-PRONGS COOKING RANGE OUTLET ACUO AIRCONDITIONING OUTLET CIRCUIT HOMERUN FOR LIGHTING (NUMBERS INSIDE CIRCLES IDENTIFY THE CIRCUITS) CIRCUIT HOMERUN FOR APPLIANCE OUTLETS S3w THREE-WAY SWITCH WHO WATER HEATER OUTLET WMO WASHING MACHINE WITH DRYER OUTLET LPP I LIGHTING AND POWER PANELBOARD Q TV ANTENNA OUTLET MATVE MASTER ANTENNA TV OUTLET/ CABINET TTC E TELEPHONE TERMINAL CABINET TELEPHONE OUTLET V TELEPHONE EXTENSION/ INTERCOMMUNICATION E LEGEND/ ELECTRICAL SYMBOLS 1
Expert Solution
steps

Step by step

Solved in 2 steps

Blurred answer
Knowledge Booster
Analog to digital converters
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.
Similar questions
  • SEE MORE QUESTIONS
Recommended textbooks for you
Power System Analysis and Design (MindTap Course …
Power System Analysis and Design (MindTap Course …
Electrical Engineering
ISBN:
9781305632134
Author:
J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:
Cengage Learning
Electric Motor Control
Electric Motor Control
Electrical Engineering
ISBN:
9781133702818
Author:
Herman
Publisher:
CENGAGE L