For the following Ladder code, what are the elements needed to convert it into FBD? Stop_PB JE Start PB ЭЕ -TON- Timer On Delay Timer Delay Tmr KENY Delay_Tmr.EN Preset Accum 1000 (DN) 0+ ○ a. 1 IREF, 1 two input BAND, 1 two input BOR, 1 BNOT, 1 timer block, a feedback without assume data available indicator O b. 2 IREF, 1 two input BAND, 1 two input BOR, 1 BNOT, 1 timer block, a feedback without assume data available indicator ○ c. None of the choices O d. 1 IREF, 1 two input BAND, 1 two input BOR, 1 BNOT, 1 timer block, a feedback with assume data available indicator e. 2 IREF, 1 two input BAND, 1 two input BOR, 1 BNOT, 1 timer block, a feedback with assume data available indicator

EBK ELECTRICAL WIRING RESIDENTIAL
19th Edition
ISBN:9781337516549
Author:Simmons
Publisher:Simmons
Chapter32: Standby Power Systems
Section: Chapter Questions
Problem 7R: Briefly explain the function of a transfer switch. _____
icon
Related questions
Question
For the following Ladder code, what are the elements needed to convert it into FBD?
Stop_PB
Start PB
E
ЭЕ
-TON-
Timer On Delay
KENY
Timer
Delay_Tmr.EN
Preset
Delay_Tmr
1000 (DN)
JE
Accum
0
○ a.
1 IREF, 1 two input BAND, 1 two input BOR, 1 BNOT, 1 timer block, a feedback without assume data available indicator
○ b. 2 IREF, 1 two input BAND, 1 two input BOR, 1 BNOT, 1 timer block, a feedback without assume data available indicator
○ c. None of the choices
○ d. 1 IREF, 1 two input BAND, 1 two input BOR, 1 BNOT, 1 timer block, a feedback with assume data available indicator
O e.
2 IREF, 1 two input BAND, 1 two input BOR, 1 BNOT, 1 timer block, a feedback with assume data available indicator
Transcribed Image Text:For the following Ladder code, what are the elements needed to convert it into FBD? Stop_PB Start PB E ЭЕ -TON- Timer On Delay KENY Timer Delay_Tmr.EN Preset Delay_Tmr 1000 (DN) JE Accum 0 ○ a. 1 IREF, 1 two input BAND, 1 two input BOR, 1 BNOT, 1 timer block, a feedback without assume data available indicator ○ b. 2 IREF, 1 two input BAND, 1 two input BOR, 1 BNOT, 1 timer block, a feedback without assume data available indicator ○ c. None of the choices ○ d. 1 IREF, 1 two input BAND, 1 two input BOR, 1 BNOT, 1 timer block, a feedback with assume data available indicator O e. 2 IREF, 1 two input BAND, 1 two input BOR, 1 BNOT, 1 timer block, a feedback with assume data available indicator
Expert Solution
steps

Step by step

Solved in 3 steps

Blurred answer
Knowledge Booster
Register
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.