A three-phase synchronous generator is being used as a source of power for a farm in a remote area of Sindh. The apparent power rating of this generator is 100 KVA and the line to line voltage is 3000 V at 50 Hz. The configuration is star. When the terminals of the alternator are short-circuited, and a field current of 40 A is applied, a short circuit current of 200 A flows where when the terminals are open-circuited, with the same field current 1040 V are measured across the terminals. Calculate the voltage regulation for fully loaded conditions having the PF of both 0.8 leading as well as lagging. Use phasor diagrams. The effective armature resistance of this generator is 0.2 ohms. (Hint: Synchronous Impedance = (O.C Voltage/phase) / (S.C Current/phase))

Introductory Circuit Analysis (13th Edition)
13th Edition
ISBN:9780133923605
Author:Robert L. Boylestad
Publisher:Robert L. Boylestad
Chapter1: Introduction
Section: Chapter Questions
Problem 1P: Visit your local library (at school or home) and describe the extent to which it provides literature...
icon
Related questions
Question
A three-phase synchronous generator is being used as a source of power for a
farm in a remote area of Sindh. The apparent power rating of this generator is
100 KVA and the line to line voltage is 3000 V at 50 Hz. The configuration is
star. When the terminals of the alternator are short-circuited, and a field current
of 40 A is applied, a short circuit current of 200 A flows where when the
terminals are open-circuited, with the same field current 1040 V are measured
across the terminals.
Calculate the voltage regulation for fully loaded conditions having the PF of
both 0.8 leading as well as lagging. Use phasor diagrams. The effective
armature resistance of this generator is 0.2 ohms.
(Hint: Synchronous Impedance = (O.C Voltage/phase) / (S.C Current/phase))
Transcribed Image Text:A three-phase synchronous generator is being used as a source of power for a farm in a remote area of Sindh. The apparent power rating of this generator is 100 KVA and the line to line voltage is 3000 V at 50 Hz. The configuration is star. When the terminals of the alternator are short-circuited, and a field current of 40 A is applied, a short circuit current of 200 A flows where when the terminals are open-circuited, with the same field current 1040 V are measured across the terminals. Calculate the voltage regulation for fully loaded conditions having the PF of both 0.8 leading as well as lagging. Use phasor diagrams. The effective armature resistance of this generator is 0.2 ohms. (Hint: Synchronous Impedance = (O.C Voltage/phase) / (S.C Current/phase))
Expert Solution
steps

Step by step

Solved in 8 steps with 8 images

Blurred answer
Knowledge Booster
Analysis of Multiple Order System and Steady State Error
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.
Similar questions
  • SEE MORE QUESTIONS
Recommended textbooks for you
Introductory Circuit Analysis (13th Edition)
Introductory Circuit Analysis (13th Edition)
Electrical Engineering
ISBN:
9780133923605
Author:
Robert L. Boylestad
Publisher:
PEARSON
Delmar's Standard Textbook Of Electricity
Delmar's Standard Textbook Of Electricity
Electrical Engineering
ISBN:
9781337900348
Author:
Stephen L. Herman
Publisher:
Cengage Learning
Programmable Logic Controllers
Programmable Logic Controllers
Electrical Engineering
ISBN:
9780073373843
Author:
Frank D. Petruzella
Publisher:
McGraw-Hill Education
Fundamentals of Electric Circuits
Fundamentals of Electric Circuits
Electrical Engineering
ISBN:
9780078028229
Author:
Charles K Alexander, Matthew Sadiku
Publisher:
McGraw-Hill Education
Electric Circuits. (11th Edition)
Electric Circuits. (11th Edition)
Electrical Engineering
ISBN:
9780134746968
Author:
James W. Nilsson, Susan Riedel
Publisher:
PEARSON
Engineering Electromagnetics
Engineering Electromagnetics
Electrical Engineering
ISBN:
9780078028151
Author:
Hayt, William H. (william Hart), Jr, BUCK, John A.
Publisher:
Mcgraw-hill Education,