(a) Conductors of a 3-phase,60 Hz transmission line are arranged at the corners of a triangle of sides 20, 5, and 8 meters. The diameter of each line conductor is 1 cm. Calculate the capacitance (C1) per phase per km and capacitive reactance (Xc1)of the line. If the length of the transmission line is 64 km, determine the capacitance per phase(C2)and Capacitive reactance(Xc2). Assume En=8.854 x10-12 (b) Draw the positive, negative and zero sequence diagram of the system shown in Figure given below. Xg = j0.16 X2 = j0.17 Xo = j0.06 Line X1 =x2 = j0.10 Xo = j0.06 x4 = j0.2 13= 10.22 AY Xo = J0.15 X =X2 = X0jo.11 X -X2 - X - j0.11 Question(a) answer Capacitance (C1) in per phase per Km Capacitive reactance (Xc1) Capacitance per phase(C) Capacitive reactance (Xc2)

Power System Analysis and Design (MindTap Course List)
6th Edition
ISBN:9781305632134
Author:J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Chapter4: Transmission Line Parameters
Section: Chapter Questions
Problem 4.13P: A single-phase overhead transmission line consists of two solid aluminum conductors having a radius...
icon
Related questions
Question
Quiq plz
(a) Conductors of a 3-phase,60 Hz transmission line are arranged at the corners of a triangle of sides 20, 5, and 8 meters. The diameter of each line conductor
is 1 cm. Calculate the capacitance (C1) per phase per km and capacitive reactance (Xc1)of the line. If the length of the transmission line is 64 km, determine the
capacitance per phase(C2)and Capacitive reactance(Xc2). Assume En=8.854 x10-12
(b) Draw the positive, negative and zero sequence diagram of the system shown in Figure given below.
Xg = j0.16
Line
X2 = 0.17
X1 =x2 = j0.10
Xo = j0.06
Xo = j0.06
xa = j0.2
13= 10.22 AY
Xo = J0.15
X = X2 - X0 - j0.11
X -X2 - X - j0.11
Question(a) answer
Capacitance (C1) in per phase per Km
Capacitive reactance (Xc1)
Capacitance per phase(C2)
Capacitive reactance (Xc2)
ele
Transcribed Image Text:(a) Conductors of a 3-phase,60 Hz transmission line are arranged at the corners of a triangle of sides 20, 5, and 8 meters. The diameter of each line conductor is 1 cm. Calculate the capacitance (C1) per phase per km and capacitive reactance (Xc1)of the line. If the length of the transmission line is 64 km, determine the capacitance per phase(C2)and Capacitive reactance(Xc2). Assume En=8.854 x10-12 (b) Draw the positive, negative and zero sequence diagram of the system shown in Figure given below. Xg = j0.16 Line X2 = 0.17 X1 =x2 = j0.10 Xo = j0.06 Xo = j0.06 xa = j0.2 13= 10.22 AY Xo = J0.15 X = X2 - X0 - j0.11 X -X2 - X - j0.11 Question(a) answer Capacitance (C1) in per phase per Km Capacitive reactance (Xc1) Capacitance per phase(C2) Capacitive reactance (Xc2) ele
Expert Solution
steps

Step by step

Solved in 2 steps with 2 images

Blurred answer
Knowledge Booster
Pulse Analog Modulation (Pulse Amplitude Modulation [PAM], Pulse Width Modulation [PWM], Pulse Position Modulation [PPM])
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.
Similar questions
  • SEE MORE QUESTIONS
Recommended textbooks for you
Power System Analysis and Design (MindTap Course …
Power System Analysis and Design (MindTap Course …
Electrical Engineering
ISBN:
9781305632134
Author:
J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:
Cengage Learning