A 3-phase transformer has a nameplate rating of 30 Y MVA, 230- 3000 YkV with 10% leakage reactance and the 69 transformer connection is wye - wye. Select a base of 30 MVA and 230kV on the high - voltage side and determine the transformer reactance referred to the high-voltage side in ohms. Select one: a. 1763.332 b 176.332 c. 15.87 d. 158.72 A 3-phase transformer has a nameplate rating of 30 MVA, 230Y/69Y KV with 10% leakage reactance and the transformer connection is wye-wye. Select a base of 30 MVA and 230 kV on the high-voltage side and determine the transformer reactance referred to the high-voltage side in ohms. Select one: O a. 1763.33 N O b. 176.33 O c. 15.87 O d. 158.7

Practical Management Science
6th Edition
ISBN:9781337406659
Author:WINSTON, Wayne L.
Publisher:WINSTON, Wayne L.
Chapter2: Introduction To Spreadsheet Modeling
Section: Chapter Questions
Problem 20P: Julie James is opening a lemonade stand. She believes the fixed cost per week of running the stand...
icon
Related questions
Question
100%
typing clear i will upvotes
A 3-phase transformer has a nameplate rating of 30
Y
MVA, 230-
3000
YkV with 10% leakage reactance and the
69
transformer connection is wye - wye. Select a base of 30
MVA and 230kV on the high - voltage side and
determine the transformer reactance referred to the
high-voltage side in ohms. Select one: a. 1763.332 b
176.332 c. 15.87 d. 158.72
A 3-phase transformer has a nameplate rating of 30 MVA, 230Y/69Y KV with 10% leakage
reactance and the transformer connection is wye-wye. Select a base of 30 MVA and 230 kV on the
high-voltage side and determine the transformer reactance referred to the high-voltage side in
ohms.
Select one:
O
a. 1763.33 N
O
b. 176.33
O
c. 15.87
O
d. 158.7
Transcribed Image Text:A 3-phase transformer has a nameplate rating of 30 Y MVA, 230- 3000 YkV with 10% leakage reactance and the 69 transformer connection is wye - wye. Select a base of 30 MVA and 230kV on the high - voltage side and determine the transformer reactance referred to the high-voltage side in ohms. Select one: a. 1763.332 b 176.332 c. 15.87 d. 158.72 A 3-phase transformer has a nameplate rating of 30 MVA, 230Y/69Y KV with 10% leakage reactance and the transformer connection is wye-wye. Select a base of 30 MVA and 230 kV on the high-voltage side and determine the transformer reactance referred to the high-voltage side in ohms. Select one: O a. 1763.33 N O b. 176.33 O c. 15.87 O d. 158.7
Expert Solution
steps

Step by step

Solved in 2 steps

Blurred answer
Similar questions
  • SEE MORE QUESTIONS
Recommended textbooks for you
Practical Management Science
Practical Management Science
Operations Management
ISBN:
9781337406659
Author:
WINSTON, Wayne L.
Publisher:
Cengage,
Operations Management
Operations Management
Operations Management
ISBN:
9781259667473
Author:
William J Stevenson
Publisher:
McGraw-Hill Education
Operations and Supply Chain Management (Mcgraw-hi…
Operations and Supply Chain Management (Mcgraw-hi…
Operations Management
ISBN:
9781259666100
Author:
F. Robert Jacobs, Richard B Chase
Publisher:
McGraw-Hill Education
Business in Action
Business in Action
Operations Management
ISBN:
9780135198100
Author:
BOVEE
Publisher:
PEARSON CO
Purchasing and Supply Chain Management
Purchasing and Supply Chain Management
Operations Management
ISBN:
9781285869681
Author:
Robert M. Monczka, Robert B. Handfield, Larry C. Giunipero, James L. Patterson
Publisher:
Cengage Learning
Production and Operations Analysis, Seventh Editi…
Production and Operations Analysis, Seventh Editi…
Operations Management
ISBN:
9781478623069
Author:
Steven Nahmias, Tava Lennon Olsen
Publisher:
Waveland Press, Inc.