6. A 4.6-kV, three-phase transmission line is 100 km long. This line has a per-phase series resistance of R = 0.125 2 per km, inductance of L = 1.25 mili Henry per km, and capacitance of C= 10-8 Farad. The line-to-line voltage at the receiving end is kept constant at 4.6 kV. Load current is 10 Amperes. Calculate sending-end voltage using short line approximation.

Power System Analysis and Design (MindTap Course List)
6th Edition
ISBN:9781305632134
Author:J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Chapter4: Transmission Line Parameters
Section: Chapter Questions
Problem 4.27MCQ: In terms of line-to-line capacitance, the line-to-neutral capacitance of a single-phase transmission...
icon
Related questions
icon
Concept explainers
Question

Frequency is 50 hz.

 

6. A 4.6-kV, three-phase transmission line is 100 km long. This line has a per-phase series.
resistance of R = 0.125 2 per km, inductance of L = 1.25 mili Henry per km, and
capacitance of C= 10-8 Farad. The line-to-line voltage at the receiving end is kept constant
at 4.6 kV. Load current is 10 Amperes. Calculate sending-end voltage using short line
approximation.
=
7. A 4.6-kV, three-phase transmission line is 100 km long. This line has a per-phase series
resistance of R = 0.125 2 per km, inductance of L 1.25 mili Henry per km, and
capacitance of C= 10-8 Farad. The line-to-line voltage at the receiving end is kept constant
at 4.6 kV. Load current is 10 Amperes. Calculate sending-end voltage using medium line
approximation.
Transcribed Image Text:6. A 4.6-kV, three-phase transmission line is 100 km long. This line has a per-phase series. resistance of R = 0.125 2 per km, inductance of L = 1.25 mili Henry per km, and capacitance of C= 10-8 Farad. The line-to-line voltage at the receiving end is kept constant at 4.6 kV. Load current is 10 Amperes. Calculate sending-end voltage using short line approximation. = 7. A 4.6-kV, three-phase transmission line is 100 km long. This line has a per-phase series resistance of R = 0.125 2 per km, inductance of L 1.25 mili Henry per km, and capacitance of C= 10-8 Farad. The line-to-line voltage at the receiving end is kept constant at 4.6 kV. Load current is 10 Amperes. Calculate sending-end voltage using medium line approximation.
Expert Solution
trending now

Trending now

This is a popular solution!

steps

Step by step

Solved in 2 steps with 1 images

Blurred answer
Knowledge Booster
Transmission line parameter
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.
Similar questions
  • SEE MORE QUESTIONS
Recommended textbooks for you
Power System Analysis and Design (MindTap Course …
Power System Analysis and Design (MindTap Course …
Electrical Engineering
ISBN:
9781305632134
Author:
J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:
Cengage Learning