1.A single phase transmission line has two parallel conductors 1·5 metres apart, the diameter of each conductor being 0·5 cm. Calculate line to neutral capacitance for a line 80 km long.

Power System Analysis and Design (MindTap Course List)
6th Edition
ISBN:9781305632134
Author:J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Chapter4: Transmission Line Parameters
Section: Chapter Questions
Problem 4.23P
icon
Related questions
icon
Concept explainers
Question

1.A single phase transmission line has two parallel conductors 1·5 metres apart, the diameter of each conductor being 0·5 cm. Calculate line to neutral capacitance for a line 80 km long.

 2.A 200 km, 3-phase transmission line has its conductors placed at the corners of an equilateral triangle of 2·5 m side. The radius of each conductor is 1 cm. Calculate:

(i) line to neutral capacitance of the line,

(ii) charging current per phase if the line is maintained at 66 kV, 50 Hz.

 [(i) 2·02 μF (ii) 24·2 A]

  1. The three conductors A, B and C of a 3-φ line are arranged in a horizontal plane with DAB = 2 m and DBC = 2·5 m. Find line-to-neutral capacitance per km if diameter of each conductor is 1·24 cm. The conductorsare transposed at regular intervals. 

[0·0091 μF/km]

  1. The three conductors of a 3-φ line are arranged at the corners of a right angled isosceles triangle. If each equal side of this triangle is 2 m, find line-to-neutral capacitance per km. Take the diameter of each conductor as 1·24 cm. The conductors are transposed at regular intervals. [0·0094 μF/km
  2. A 3-phase, 50 Hz, 132 kV overhead line has conductors placed in a horizontal plane 4·56 m apart. Conductor diameter is 22·4 mm. If the line length is 100 km, Calculate the charging current per phase, assuming complete transposition. [21·345 A]

6. Three conductors of a 3-phase overhead line are arranged in a horizontal plane 6 m apart. The diameter of each conductor is 1·24 cm. Find the capacitance of each conductor to neutral per 100 km of the line.

Expert Solution
trending now

Trending now

This is a popular solution!

steps

Step by step

Solved in 4 steps with 3 images

Blurred answer
Knowledge Booster
Transmission line parameter
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.
Similar questions
  • SEE MORE QUESTIONS
Recommended textbooks for you
Power System Analysis and Design (MindTap Course …
Power System Analysis and Design (MindTap Course …
Electrical Engineering
ISBN:
9781305632134
Author:
J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:
Cengage Learning